{"product_id":"live-electrical-32a-3p-n-b-curve-type-a-rcbo-10ka-30ma","title":"LIVE Electrical 32A 3P+N B Curve Type A RCBO 10kA 30mA","description":"\u003cdiv style=\"font-family:inherit;color:#1f2329;line-height:1.65;max-width:960px;margin:0 auto\"\u003e\n\u003cdiv style=\"background:#1f2329;color:#fff;border-radius:10px;padding:22px 24px;margin-bottom:22px;border-bottom:5px solid #e8381b\"\u003e\n\u003cdiv style=\"font-size:12px;letter-spacing:2px;text-transform:uppercase;color:#ff8a70;font-weight:700;margin-bottom:6px\"\u003eLIVE Electrical • RCBOs\u003c\/div\u003e\n\u003cdiv style=\"font-size:24px;font-weight:800;line-height:1.25;margin-bottom:10px\"\u003eLIVE Electrical 32A 3P+N B Curve Type A RCBO 10kA 30mA\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;color:#d6d9de\"\u003eThe LIVE Electrical RTN332B-030N is a robust 3P+N Type A RCBO that provides complete protection for three-phase installations.\u003c\/div\u003e\n\u003cdiv style=\"margin-top:14px\"\u003e\u003cspan style=\"display:inline-block;background:#e8381b;color:#fff;font-size:13px;font-weight:700;border-radius:20px;padding:5px 12px;margin:4px 6px 0 0\"\u003eIn Stock\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:16px;margin:0 0 16px\"\u003eThe LIVE Electrical RTN332B-030N is a robust 3P+N Type A RCBO that provides complete protection for three-phase installations. Combining overload, short circuit, and residual current protection into a single compact device, this RCBO offers superior performance and safety. With a 32A B Curve tripping characteristic and a 10kA breaking capacity, it is ideally suited for a wide range of commercial, industrial, and light commercial applications. Conforming to BS EN 61009-1, the RTN332B-030N is designed to detect both AC and pulsating DC residual currents, ensuring protection against faults from modern equipment such as EV chargers, LED drivers, and variable speed drives. Its high reliability and compact modular design make it easy to install in standard three-phase consumer and distribution boards.\u003c\/p\u003e\n\u003ch2 style=\"font-size:19px;font-weight:800;margin:6px 0 12px;color:#1f2329\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"margin:0 0 24px;padding-left:20px;font-size:15px\"\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eProvides overload, short circuit, and residual current protection in one compact unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003e10kA high breaking capacity ensures safe operation under fault conditions.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eType A sensitivity ensures effective protection against AC and pulsating DC leakage currents.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eB Curve tripping ideal for lighting, socket outlet, and general-purpose circuits.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eCompact modular construction simplifies installation and maintenance.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003ePerfect for commercial panels, industrial systems, and EV infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:19px;font-weight:800;margin:6px 0 12px;color:#1f2329\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;border:1px solid #e4e6ea;margin-bottom:24px\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#1f2329;color:#fff;text-align:left;padding:10px 12px;font-size:14px\"\u003eLIVE Electrical 32A 3P+N B Curve Type A RCBO 10kA 30mA\u003c\/th\u003e\u003c\/tr\u003e\n\n\n\n\n\n\n\n\u003ctr style=\"background:#f7f8fa\"\u003e\n\u003ctd style=\"padding:9px 12px;width:40%;font-weight:700;vertical-align:top\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px\"\u003eLIVE Electrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f8fa\"\u003e\n\u003ctd style=\"padding:9px 12px;width:40%;font-weight:700;vertical-align:top\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px\"\u003eRTN332B-030N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f8fa\"\u003e\n\u003ctd style=\"padding:9px 12px;width:40%;font-weight:700;vertical-align:top\"\u003eEAN\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px\"\u003e5060926593753\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f8fa\"\u003e\n\u003ctd style=\"padding:9px 12px;width:40%;font-weight:700;vertical-align:top\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px\"\u003eRCBOs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f8fa\"\u003e\n\u003ctd style=\"padding:9px 12px;width:40%;font-weight:700;vertical-align:top\"\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px\"\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f8fa\"\u003e\n\u003ctd style=\"padding:9px 12px;width:40%;font-weight:700;vertical-align:top\"\u003eRated Voltage (Ue)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px\"\u003e230\/400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f8fa\"\u003e\n\u003ctd style=\"padding:9px 12px;width:40%;font-weight:700;vertical-align:top\"\u003eBreaking Capacity (Icn)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px\"\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f8fa\"\u003e\n\u003ctd style=\"padding:9px 12px;width:40%;font-weight:700;vertical-align:top\"\u003eRated Residual Current\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px\"\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f8fa\"\u003e\n\u003ctd style=\"padding:9px 12px;width:40%;font-weight:700;vertical-align:top\"\u003ePole Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px\"\u003e3P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f8fa\"\u003e\n\u003ctd style=\"padding:9px 12px;width:40%;font-weight:700;vertical-align:top\"\u003eTripping Curve\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px\"\u003eB Curve – suitable for resistive and low-inductive loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f8fa\"\u003e\n\u003ctd style=\"padding:9px 12px;width:40%;font-weight:700;vertical-align:top\"\u003eResidual Current Type\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px\"\u003eType A – detects both AC and pulsating DC leakage currents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f8fa\"\u003e\n\u003ctd style=\"padding:9px 12px;width:40%;font-weight:700;vertical-align:top\"\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px\"\u003eInput: up to 16mm² Output: up to 10mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f8fa\"\u003e\n\u003ctd style=\"padding:9px 12px;width:40%;font-weight:700;vertical-align:top\"\u003eInput\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px\"\u003eup to 16mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f8fa\"\u003e\n\u003ctd style=\"padding:9px 12px;width:40%;font-weight:700;vertical-align:top\"\u003eOutput\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px\"\u003eup to 10mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f8fa\"\u003e\n\u003ctd style=\"padding:9px 12px;width:40%;font-weight:700;vertical-align:top\"\u003eStandard Compliance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px\"\u003eBS EN 61009-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f8fa\"\u003e\n\u003ctd style=\"padding:9px 12px;width:40%;font-weight:700;vertical-align:top\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px\"\u003e0.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"background:#f7f8fa;border-radius:10px;padding:16px 18px;margin-bottom:24px\"\u003e\n\u003ch2 style=\"font-size:16px;font-weight:800;margin:0 0 4px\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cdiv style=\"font-size:14px;color:#4a4f57\"\u003e1 x LIVE Electrical 32A 3P+N B Curve Type A RCBO 10kA 30mA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:4px solid #e8381b;background:#fff5f2;border-radius:6px;padding:12px 16px;margin-bottom:24px\"\u003e\n\u003ch3 style=\"font-size:15px;font-weight:800;margin:0 0 4px\"\u003eGood To Know\u003c\/h3\u003e\n\u003cdiv style=\"font-size:14px;color:#4a4f57\"\u003eFixed electrical products should be installed by a qualified electrician in line with current wiring regulations (BS 7671).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-size:19px;font-weight:800;margin:6px 0 12px;color:#1f2329\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 style=\"font-size:15px;font-weight:800;margin:12px 0 4px\"\u003eHow quickly will my order be dispatched?\u003c\/h3\u003e\n\u003cp style=\"font-size:14px;color:#4a4f57;margin:0 0 8px\"\u003eThis item is in stock and is usually dispatched within 1 working day.\u003c\/p\u003e\n\u003ch3 style=\"font-size:15px;font-weight:800;margin:12px 0 4px\"\u003eWhat is the manufacturer part number?\u003c\/h3\u003e\n\u003cp style=\"font-size:14px;color:#4a4f57;margin:0 0 8px\"\u003eThis is the LIVE Electrical RTN332B-030N (EAN 5060926593753).\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom:20px\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin-bottom:14px\"\u003e\n\u003cdiv style=\"flex:1 1 200px;background:#1f2329;color:#fff;border-radius:10px;padding:14px;text-align:center\"\u003e\n\u003cdiv style=\"font-weight:800;font-size:14px\"\u003eFree UK Delivery\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;color:#c9ccd1\"\u003eOn orders over £40\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 200px;background:#1f2329;color:#fff;border-radius:10px;padding:14px;text-align:center\"\u003e\n\u003cdiv style=\"font-weight:800;font-size:14px\"\u003eFree Next Day\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;color:#c9ccd1\"\u003eOn orders over 2kg\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 200px;background:#1f2329;color:#fff;border-radius:10px;padding:14px;text-align:center\"\u003e\n\u003cdiv style=\"font-weight:800;font-size:14px\"\u003eTrade Quantities\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;color:#c9ccd1\"\u003eSent from the UK\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 200px;background:#1f2329;color:#fff;border-radius:10px;padding:14px;text-align:center\"\u003e\n\u003cdiv style=\"font-weight:800;font-size:14px\"\u003eNo-Quibble Returns\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;color:#c9ccd1\"\u003eJust send it back\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":58449902305662,"sku":"B2B-RTN332B-030N","price":59.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0243\/9069\/7024\/files\/RTN350C-030N_f059c6b0-038b-46f5-ab63-5be6e4d8f29f.webp?v=1794504429","url":"https:\/\/fixingking.com\/products\/live-electrical-32a-3p-n-b-curve-type-a-rcbo-10ka-30ma","provider":"Fixing King","version":"1.0","type":"link"}